A possible

A possible selleck chemicals llc caveat of this supposition is that there was also a difference in achieved Hb levels between dialysis patients in Japan and those in the other DOPPS countries. However, the Japanese Society for Dialysis Therapy explained the difference between Japan and other

countries by timing of blood collection and patient position at blood collection. Blood sampling for studies of Hb levels is performed at the beginning of the week in Japan, whereas it is generally performed on the middle day of the week in the other countries [62]. This difference in sampling time could affect the rate of weight gain and plasma volume. In addition, the supine position at blood collection may further decrease the Hb values in Japan, whereas the majority of patients in the other countries undergo MHD in a sitting position on a chair-bed. Further investigation is needed to clarify the cause underlying the differences in ferritin and Hb levels between EPZ-6438 manufacturer dialysis patients in Japan and other countries. Conclusion It has long been recognized that the most

common cause of incomplete ESA response is limited iron availability, and that iron supplementation may improve the response to ESA. Increased blood loss is inherent to the condition of hemodialysis patients. Therefore, the use of IV iron is frequently indicated to maintain iron balance. However, there is no convincing evidence that IV iron supply improves patient survival although FID is a major cause of ESA hyporesponsiveness which itself is tightly associated with the poor outcomes of anemic patients with CKD. The discovery of hepcidin has considerably PD184352 (CI-1040) improved our understanding of the regulation of iron metabolism and related disorders. It has also profoundly changed our view of iron supplementation. When hepcidin concentrations are high, FPN is internalized, iron is trapped in macrophages, DMT1 is degraded, and iron absorption in the intestine is minimal.

Based on the close correlation between ferritin and hepcidin, iron administration should increase hepcidin levels, which in turn should not only reduce the release of iron and its transport from the RES (storage tissues) but also decrease iron absorption from the gut. These effects are consistent with findings in ACD patients as well as in those with FID. We suggest that physicians be cautious in prescribing IV iron in patients with FID, even if the immediate effect is an improvement in the anemia management of iron-replete MHD patients. No long-term safety data exist with respect to the effects of prolonged IV iron therapy on hard patient outcomes. Large randomized prospective cohort studies are needed to answer the question of whether a better MHD patient survival is achieved with less ESA and more IV iron or more ESA and less IV iron.

No related posts.

Comments are closed.