The study was approved by the ethical committee of the University

The study was approved by the ethical committee of the University Hospital ALK inhibitor Maastricht and Maastricht University, and all participants signed written learn more informed consent after having received proper information about the study before performing any of the study procedures. DNA extraction Blood samples

DNA was extracted from blood in an automated procedure using Maxwell 16 DNA purification Kits on the Maxwell 16 instrument (Promega, Madison, WI) 400 μl of blood collected in EDTA-tubes were used and the isolation procedure was performed according to the manufacturer’s instructions. Saliva samples For collection of a small amount of saliva for DNA extraction, we used a plain cotton swab collection device (SalivetteTM: Sarstedt AG & Co. Numbrecht, Germany). Upon return, the SalivetteTM containing the saliva swab was stored in a refrigerator at 4 °C until DNA extraction. First, the swab kept in the collection

tube was centrifuged at 4,000 rpm for 10 min, and the saliva was transferred to a 15 mL Nunc-tube which was kept at 5 °C overnight. Using a pair of sterile tweezers, the Cyclosporin A mouse swab was then transferred from the collection tube to a 50 mL Nunc-tube; 4 mL sterile water was added and the tube was kept at room temperature overnight. The next day, the swab plus water was transferred back into the collection tube and again centrifuged at 4,000 rpm for 10 min, the saliva yield was again transferred to the 15 mL Nunc-tube already containing the saliva yield from the day before. Next, cells were isolated from the saliva by centrifuging Rolziracetam the saliva-containing 15 mL Nunc-tube at 4,000 rpm for 10 min. Subsequently, the supernatant was carefully removed, leaving 600–800 μl over the pellet. DNA extraction was then carried out using Maxwell 16 DNA purification Kits on the Maxwell 16 instrument (Promega, Madison, WI) according to the manufacturer’s instructions. Genotyping The study population was genotyped for 15 non-synonymous SNPs within the P2RX7 that were selected based on their previously published functional effects on the P2X7R, or were found

in the dbSNP database for non-synonymous SNPs (Fig. 1). Genotyping was done by Sequenom (Sequenom, Hamburg, Germany) using the Sequenom MassARRAY® iPLEX Gold assay. To assess the accuracy of the genotyping assay, an internal validation study was performed in which a randomly selected number of samples (N = 45) were genotyped a second time, using restriction enzyme digestion of appropriate PCR products or Taqman assay. This was done according to our previously published protocol [22]. When the results were compared with the original genotyping we observed a discrepancy between the two different genotyping methods of ∼4.2 %. The discrepancy appeared to be smaller (∼2.7 %) if the original genotyping with the Sequenom MassARRAY ® iPLEX Gold assay had failed for a maximum of one SNP.

No related posts.

Comments are closed.