This success was followed by establishment of the Transplantation

This success was followed by establishment of the Transplantation Institute of the Warsaw Medical Academy in 1975, which facilitated the scientific and clinical growth of nephrology and transplantation in Poland. He also introduced and established scientific evidence for the use of immunosuppressive therapy for glomerular diseases. The heritage of Tadeusz Orlowski is broader than nephrology. His legacy will continue through the work of the

many who learned from his example.”
“Femoroacetabular impingement is a relatively recently described cause of hip pain that involves degenerative change in the hips of younger patients (less than thirty-five years old) as a result of predisposing pathoanatomy. The two types of impingement, cam and pincer, often occur together and overlap to varying degrees. selleck compound The diagnostic workup begins with radiography, but magnetic resonance imaging and magnetic resonance arthrography provide more accurate imaging

that characterizes not only the pathoanatomy but also other associated findings, including labral tears and cartilage damage.”
“Two Greek manuscripts have preserved a short treatise On the Diagnosis of Kidney Pathologies and Their Treatment attributed to Galen. In the present article, I study the content of this work and suggest that it may describe the effect of gout on the kidneys, unless it describes pseudog-out, that is, chondrocalsinosis of kidneys. On this basis, I suggest learn more that the treatise is not by Galen, but by the 15th-century Byzantine physician Demetrios Pepagomenos.”
“Computer navigation of total hip arthroplasty and computer simulation of hip motions based on collision detection were both introduced more than ten years ago. Neither of these promising technologies has achieved its full potential to improve patient outcomes. SN-38 nmr Combining these two technologies

allows the individual strengths of each to more easily demonstrate hip kinematics in a clinically useful way. All normal and pathologic combined hip motions must be clearly and accurately reported to fully evaluate the kinematics involved in total hip arthroplasty, femoroacetabular impingement syndrome, and other hip disorders. The use of three-dimensional data graphs allows for a rapid and thorough evaluation of the very large data sets that are required for the purpose of making a complete report of all combined hip motions. Data can be obtained from simulations made with use of high-resolution computed tomographic scans and computer-aided implant-design files or from clinically obtained motion analysis on fresh cadavers or normal subjects. The use of these methods and graphics allows for the thorough evaluation of the geometries of current implant designs and will help improve future implant designs.

No related posts.

Comments are closed.